A10/W10 - Motor Overload fault in danfoss drive
A10/W10 - Motor Overload fault in danfoss drive
Cause: The motor is drawing excessive current for an extended period, indicating it is overloaded or stalled. This is a protective function based on the drive's electronic thermal relay (ETR).
Solution:
Cause: The motor is drawing excessive current for an extended period, indicating it is overloaded or stalled. This is a protective function based on the drive's electronic thermal relay (ETR).
Solution:
- Check for mechanical issues causing the overload, such as jammed machinery or bad bearings.
- Verify that the motor nameplate data is correctly entered in the drive's parameters.
- Ensure the motor is not undersized for the application.
- If the motor has its own cooling fan, ensure it is operational.