SP9013 (Alarm 13) Spindle CPU Data Memory Error fault in Fanuc drive
SP9013 (Alarm 13) Spindle CPU Data Memory Error fault in Fanuc drive
Description
SP9013 (Alarm 13) is a "Death Screen" for the Spindle Amplifier. It indicates that the internal CPU on the spindle drive's control board attempted to read/write to its own RAM or EEPROM and failed. This is a checksum error or a hardware read failure. The drive's "Brain" is effectively corrupted and cannot run the software required to control the motor.
Cause
- Board Aging: The solder joints on the memory chips have cracked due to thermal cycling over 15-20 years.
- Power Surge: A voltage spike entered the 24V control power line and damaged the logic chips.
- Contamination: Conductive dust or coolant mist has bridged pins on the control PCB.
Solution
- Reseat Control Card: If the spindle drive is a modular unit, power down, remove the faceplate control card, clean the edge connector, and reinstall it.
- Replace Drive: In 95% of cases, Alarm 13 requires replacing the Spindle Amplifier or sending it to a specialized lab for board-level repair (replacing memory chips).