Posts

Showing posts from June, 2026

L&T SX2000 Drive Fault Codes List

Complete reference list of L&T SX2000 High-Performance drive fault codes. Learn to troubleshoot heavy-duty errors like oL1 (Motor Overload), oL2 (Drive Overload), and CPF hardware faults. L&T SX2000 Fault Codes Reference Table Below list show L&T SX2000 Drive Fault Codes List:   Fault Codes Cause & Solution OLt Over Load Cause : Displayed when the motor overload trip is activated and the actual load level exceeds the set level. Operates when PRT-20 is set to a value other than 0. Solution : 1. Ensure that the motor and inverter have appropriate capacity ratings. 2. Increase the set value for the overload trip level. ULt Underload Cause : Displayed when the motor underload trip is activated and the actual load level is less than the set level. Operates when PRT-27 is set to a value other than 0. Solution : - Replace the motor and inverter with models with lower capac...

L&T CX2000 Drive Fault Codes List

Complete reference list of L&T CX2000 (Larsen & Toubro) AC drive fault codes. Learn to troubleshoot common errors like OC (Overcurrent), OV (Overvoltage), and reset procedures. L&T CX2000 Fault Codes Reference Table Use the search bar in the table below to quickly find your specific error code. Fault Codes Cause & Solution OCt Over current   Cause : The inverter turns off its output when the output current of the inverter flows more than the inverter rated current. - The acceleration or deceleration is too fast; - The voltage of the grid is too low; - The power of the VFD is too low; - The load transients or is abnormal; - The grounding is short circuited or the output is phase loss; - There is strong external interference; - The overvoltage stall protection is not open. Solution : - Increase the ACC time; - Check the input power; - Select the VFD with a l...

Inovance MD200 Drive Fault Codes List

A comprehensive guide to Inovance MD200 mini drive fault codes. Learn to interpret Err codes, access historical data via the keypad, and resolve general purpose drive issues. Inovance MD200 Fault Codes Reference Table Below is the complete list of fault codes and troubleshooting actions associated with the MD200 series. Fault Codes Cause & Solution Err02 Overcurrent during acceleration Cause & Solution : 1. Ground fault or short circuit exists in the output circuit . - Check whether short-circuit occurs on the motor, the motor cable or contactor. 2. Acceleration time is too short . - Increase acceleration time. 3. Customized torque boost or V/F curve is not appropriate . - Adjust the customized torque boost or V/F curve. 4. The voltage is too low . - Adjust the voltage to normal range. 5. The spinning motor is started . - Enable the catching a spinning motor function or ...

Inovance MD800 Drive Fault Codes List

A comprehensive guide to Inovance MD800 multidrive fault codes. Learn to interpret Err codes, use InoDriveShop for diagnostics, and resolve multidrive issues. Inovance MD800 Fault Codes Reference Table Below is the complete list of error codes and alarm definitions associated with the MD800 multidrive system. Fault Codes Cause & Solution E01.06 STO model identification error Cause : The hardware is faulty. Solution : - Check the AC drive nameplate to confirm whether the AC drive has the STO function. - After this same fault comes then there is an hardware or software issue in drive. Need to repair or replace drive. E01.07 AC drive axis type identification setting error Cause : The hardware is faulty. Solution : - Check the AC drive nameplate to confirm the axis type (single-axis or dual-axis) of the AC drive. E02.04 Overcurrent during ...