Toshiba Q7 Fault Codes List
Troubleshoot your legacy Toshiba Q7 (Flowmate) drive with our updated fault code guide. Learn to interpret OC, OL, and EF trips, view past faults, and reset the drive safely.
Toshiba Q7 Fault Codes Reference Table
Below is the complete list of trip codes and alarms. Please refer to this table to match the code on your display with the specific hardware or parameter issue.
Toshiba Q7 ASD Faults, Alarms, and Trips
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| CM1 Comm1 Error (Internal communications error) |
Cause:
Remedy:
|
| CM2 Comm2 Error (External communications error) |
Cause:
Remedy:
|
| EMG Emergency Off |
Cause:
Remedy:
|
| MOFF Main Undervoltage |
Cause:
Remedy:
|
| OC Over Current |
Cause:
Remedy:
|
| *OH Overheat |
Cause:
Remedy:
|
| OJ Timer (Run-time counter exceeded) |
Cause:
Remedy:
|
| *OLI ASD Overload |
Cause:
Remedy:
|
| OLM Motor Overload |
Cause:
Remedy:
|
| *OLR Resistor Overload |
Cause:
Remedy:
|
| *OP Overvoltage |
Cause:
Remedy:
|
| OT Overtorque |
Cause:
Remedy:
|
| *POFF Control Undervoltage |
Cause:
Remedy:
|
| PtSt Reference Point |
Cause:
Remedy:
|
| UC Undercurrent |
Cause:
Remedy:
|
| Atn Autotune Active |
Cause:
Remedy:
|
| db / dbOn DC Braking Active |
Cause:
Remedy:
|
| Inverter (ASD) OL Inverter Overload Trip |
Cause:
Remedy:
|
| Autotuning Err Autotuning Error |
Cause:
Remedy:
|
| Comm Error Communication Error |
Cause:
Remedy:
|
| Ctrl Undervolts Control Undervoltage |
Cause:
Remedy:
|
| CPU Error CPU Malfunction |
Cause:
Remedy:
|
| Main Undervolts Main Undervoltage |
Cause:
Remedy:
|
| Fuse Fuse Open |
Cause:
Remedy:
|
| DBR Overcurrent DBR Overcurrent |
Cause:
Remedy:
|
| DBR Overload DBR Overload |
Cause:
Remedy:
|
| GND Fault Ground Fault |
Cause:
Remedy:
|
| Ctrl EEPROM Err Control EEPROM Error |
Cause:
Remedy:
|
| EEPROM Write Err EEPROM Write Error |
Cause:
Remedy:
|
| E-Off Emergency Off |
Cause:
Remedy:
|
| Encoder Loss Encoder Loss |
Cause:
Remedy:
|
| Flash Error Flash Memory Error |
Cause:
Remedy:
|
| Gate Array Error Gate Array Error |
Cause:
Remedy:
|
| In(put) Phase Loss Input Phase Loss |
Cause:
Remedy:
|
| Load Drooping Load Drooping |
Cause:
Remedy:
|
| Load End OC Load End Overcurrent |
Cause:
Remedy:
|
| Under Curr(ent) Trip Undercurrent Trip |
Cause:
Remedy:
|
| Main EEPROM Err Main EEPROM Error |
Cause:
Remedy:
|
| Motor Overload Motor Overload |
Cause:
Remedy:
|
| Option PCB Error Option PCB Error |
Cause:
Remedy:
|
| Out(put) Phase Loss Output Phase Loss |
Cause:
Remedy:
|
| Overcurrent Acc Overcurrent during Accel |
Cause:
Remedy:
|
| Overcurrent Dec Overcurrent during Decel |
Cause:
Remedy:
|
| Overcurrent Run Overcurrent during Run |
Cause:
Remedy:
|
| Overheat Overheat |
Cause:
Remedy:
|
| Speed Error Speed Error |
Cause:
Remedy:
|
| Overtorque Overtorque |
Cause:
Remedy:
|
| Overvolt Accel Overvoltage during Accel |
Cause:
Remedy:
|
| Overvolt Decel Overvoltage during Decel |
Cause:
Remedy:
|
| Overvolt Run Overvoltage during Run |
Cause:
Remedy:
|
| Positional Err Positional Error |
Cause:
Remedy:
|
| RAM/ROM Err RAM or ROM Error |
Cause:
Remedy:
|
| Sink/Source Error Sink/Source Configuration Error |
Cause:
Remedy:
|
| Type(form) Error Typeform Error |
Cause:
Remedy:
|
| U/V/W Phase OC Phase Overcurrent (U, V, or W) |
Cause:
Remedy:
|
How to Read Q7 Faults via Keypad
Since the Q7 is a legacy drive, connecting it to modern software can be difficult. In 2026, the on-board keypad (Electronic Operator Interface) is your best tool for diagnostics:
- Current Fault: When the drive trips, the display immediately flashes the fault code. Do not reset the drive until you have noted this code.
- Trip History: The Q7 stores the last 4 trips in its non-volatile memory. Press the MON (Monitor) key and use the arrow keys to scroll to the “Trip Monitor” section (often labeled as tr-1 through tr-4).
- Status at Trip: By selecting a past trip in the monitor menu, you can often view the output frequency and current at the moment of failure. This data is critical for determining if the fault happened during startup (high current) or steady-state operation.
General Troubleshooting Steps
Given the age of Q7 drives in 2026, many faults are related to component aging. Perform these checks:
- Overcurrent (OC1/OC2/OC3): OC1 is Accel, OC2 is Decel, OC3 is Constant Speed. Check for a shorted motor or ground fault. If the motor tests fine, the drive’s internal IGBT snubber circuits or capacitors may be degraded.
- Overload (OL1/OL2): OL1 is Motor Overload; OL2 is Drive Overload. Ensure the “Motor Rated Current” parameter matches the motor nameplate. Check for mechanical binding on pumps or clogged filters on fans.
- Earth Fault (EF): This indicates a current leak to the ground on the output side. Do not reset repeatedly. Disconnect the motor leads and perform a megger test on the motor and cabling immediately.
Frequently Asked Questions (FAQ)
Q: What is the difference between a “C” code and a “Trip”?
A: A flashing C code (like CL for Current Limit or CO for Overcurrent Alarm) is a warning that the drive is actively compensating to prevent a trip. A Trip (like OC1) stops the output completely.
Q: How do I reset a Toshiba Q7 fault?
A: You can reset the drive using one of these methods:
- Press the STOP/RESET key on the keypad.
- Momentarily short the RES (Reset) control terminal to the Common (CC) terminal.
- Cycle the main input power (Turn OFF, wait for the display to go dark, Turn ON).
Q: Why does the drive display “OFF”?
A: OFF is the standard standby status. It means the drive has power but has not received a valid “Run” command (Forward or Reverse) from the terminal strip or keypad.