F7085 fault in Siemens V70 Drive

F7085 fault in Siemens V70 Drive indicates Open-loop/closed-loop control parameters changed. This means the drive automatically adjusted your control parameters because they exceeded hardware limits or were incompatible with the current hardware features. Cause: Open-loop/closed-loop control parameters have had to be changed for the following reasons:
  • As a result of other parameters, they have exceeded the dynamic limits.
  • They cannot be used due to the fact that the hardware detected not having certain features.


Remedy: It is not necessary to change the parameters as they have already been correctly limited.