FAL fault in Emotron VSB Drive

FAL fault indicates Module protection. This means the inverter's internal hardware protection for the power module has been triggered due to abnormal operating conditions. Possible Causes: 1: Output short circuit (phase-to-phase short circuit or output ground short circuit). 2: Fan damaged or air duct blocked. 3: Direct connection of inverter module. 4: Switching power supply damaged. 5: Control board abnormal. 6: Ambient temperature is too high. 7: Loose connection of control board. 8: Overvoltage or overcurrent. Solutions: 1: Check motor connection and output ground impedance. 2: Clear the air duct or replace the fan. 3: Seek services. 4: Seek services. 5: Seek services. 6: Reduce ambient temperature. 7: Pull out and reinsert the cables of control board. 8: Handle it with the solutions of overvoltage or overcurrent.